| Tipe | Indikator téknis | |||||
| Kaluaran | Tegangan DC | 5V | 12V | 24V | 36V | 48V |
| Arus anu dipeunteun | 40A | 17A | 8.8A | 5.9A | 4.4A | |
| Kakuatan anu dipeunteun | 200W | 204W | 211.2W | 212.4W | 211.2W | |
| Riak jeung bising | 150mVp-p | 150mVp-p | 150mVp-p | 200mVp-p | 200mVp-p | |
| Rentang pangaturan tegangan | ±10% | |||||
| Presisi tegangan | ±3.0% | ±1,5% | ±1.0% | ±1.0% | ±1.0% | |
| Laju pangaturan linier | ±0,5% | ±0,5% | ±0,5% | ±0,5% | ±0,5% | |
| Laju pangaturan beban | ±2.0% | ±1.0% | ±0,5% | ±0,5% | ±0,5% | |
| Waktuna ngabéntangan | 1500ms, 50ms/230VAC 1500ms, 50ms/115VAC (beban pinuh) | |||||
| Jaga waktos | 16ms/230VAC 12ms/115VA (beban pinuh) | |||||
| Input | Rentang/frékuénsi tegangan | 90-132VAC/180-264VAC via pilihan saklar/240-370VDC 47Hz-63Hz | ||||
| Efisiensi (khas) | 87% | 88% | 90% | 89,50% | 90% | |
| Arus kerja | 4A/115VAC 2.2A/230VAC | |||||
| Arus kejut | Mimitian tiis: 60A/115VAC 60A/230VAC | |||||
| Arus bocor | <2mA 240VAC | |||||
| Ciri-ciri panyalindungan | Protéksi kaleuwihan beban | Jenis panyalindungan: mode burp, miceun kaayaan abnormal sareng otomatis balik deui ka normal | ||||
| Protéksi tegangan kaleuleuwihan | Jenis panyalindungan: tutup kaluaran sareng mimitian deui sacara otomatis ka normal | |||||
| Protéksi suhu anu kaleuleuwihi | Jenis panyalindungan: tutup kaluaran sareng mimitian deui sacara otomatis ka normal | |||||
| Élmu lingkungan | Suhu sareng kalembaban kerja | -25℃~+70℃;20%~90RH | ||||
| Suhu sareng kalembaban panyimpenan | 40℃~+85℃; 10%~95RH | |||||
| Kaamanan | Résistansi tekanan | Input – kaluaran :3KVAC input-case :2KVAC output -case: 0.5kvac durasi :1 menit | ||||
| Impedansi insulasi | Input – kaluaran sareng input – cangkang, output – cangkang: 500 VDC /100 m Ω 25℃,70% RH | |||||
| Anu sanésna | Ukuran | 215*115*30mm (P * L * T) | ||||
| Beurat bersih / beurat kotor | 660g/727g | |||||
| Catetan | (1) Pangukuran riak sareng noise: Nganggo jalur twisted-pair 12 "kalawan kapasitor 0.1uF sareng 47uF sacara paralel di terminal, pangukuran dilaksanakeun dina bandwidth 20MHz. (2) Efisiensi diuji dina tegangan input 230VAC, beban anu dipeunteun sareng suhu lingkungan 25℃. Akurasi: kalebet kasalahan setélan, laju pangaturan linier sareng laju pangaturan beban. Métode uji laju pangaturan linier: nguji ti tegangan handap ka tegangan luhur dina beban anu dipeunteun. Métode uji laju pangaturan beban: ti beban anu dipeunteun 0%-100%. Waktos ngamimitian diukur dina kaayaan mimiti tiis, sareng mesin saklar anu sering gancang tiasa ningkatkeun waktos ngamimitian. Nalika luhurna di luhur 2000 méter, suhu operasi kedah diturunkeun ku 5/1000. | |||||