IEC Listrik | 75 | 150 | 275 | 320 | ||
Tegangan AC Nominal (50/60Hz) | Uc/Un | 60V | 120V | 230V | 230V | |
Tegangan Operasi Kontinyu Maksimum (AC) | (LN) | Uc | 75V | 150V | 270V | 320V |
(N-PE) | Uc | 255V | ||||
Arus Pelepasan Nominal (8/20μs) | (LN)/(N-PE) | In | 20 kA/25 kA | |||
Arus Pelepasan Maksimum (8/20μs) | (LN)/(N-PE) | Imax | 50 kA/50 kA | |||
Impulse Discharge Ayeuna (10/350μs) | (LN)/(N-PE) | Iimp | 12,5 kA / 25 kA | |||
Énergi spésifik | (LN)/(N-PE) | W/Urang Sunda | 39 kJ/Ω / 156 kJ/Ω | |||
muatan | (LN)/(N-PE) | Q | 6,25 As / 12,5 As | |||
Tingkat panyalindungan tegangan | (LN)/(N-PE) | Up | 0,7 kV / 1,5 kV | 1,0kV / 1,5 kV | 1,5 kV / 1,5 kV | 1. 6kV / 1,5 kV |
(N-PE) | Lamun abdi | 100 ARMS | ||||
Waktu Tanggapan | (LN)/(N-PE) | tA | <25ns/<100 ns | |||
Nyadangkeun sekering (maks) | 315A / 250A gG | |||||
Peunteun Arus Sirkuit (AC) | (LN) | ISCCR | 25 kA/50 kA | |||
TOV Tahan 5s | (LN) | UT | 114V | 180V | 335V | 335V |
TOV 120 mnt | (LN) | UT | 114V | 230V | 440V | 440V |
modus | Tahan | Aman Gagal | Aman Gagal | Aman Gagal | ||
TOV Tahan 200ms | (N-PE) | UT | 1200V | |||
UL Listrik | ||||||
Tegangan Operasi Kontinyu Maksimum (AC) | MCOV | 75V / 255V | 150V / 255V | 275V / 255V | 320V / 255V | |
Peunteun Protection tegangan | VPR | 330V / 1200V | 600V / 1200V | 900V / 1200V | 1200V / 1200V | |
Arus Pelepasan Nominal (8/20μs) | In | 20 kA / 20 kA | 20 kA / 20 kA | 20 kA / 20 kA | 20 kA / 20 kA | |
Peunteun Arus Sirkuit (AC) | SCCR | 100kA | 200kA | 150kA | 150kA |