IEC Listrik | 150 | 275 | 320 | 385 | 440 | ||
Tegangan AC Nominal (50/60Hz) | 120V | 230V | 230V | 230V | 400V | ||
Tegangan Operasi Kontinyu Maksimum (AC) | (LN) | Uc | 150V | 275V | 320V | 385V | 440V |
(N-PE) | Uc | 255V | |||||
Arus Pelepasan Nominal (8/20μs) | (LN)/(N-PE) | In | 20 kV/20 kA | ||||
Arus Pelepasan Maksimum (8/20μs) | (LN)/(N-PE) | Imax | 40kA/40kA | ||||
Tingkat panyalindungan tegangan | (LN)/(N-PE) | Up | 1.0kV / 1.5kV | 1.5kV / 1.5kV | 1.6kV/1.5kV | 1,8 kV / 1,5 kV | 2.0kV / 1.5kV |
Turutan Peunteun Interupsi Ayeuna | (N-PE) | Lamun abdi | 100 ARMS | ||||
Waktu Tanggapan | (LN)/(N-PE) | tA | <25ns/<100ns | ||||
Sekering Nyadangkeun (maks) | 125A gL / gG | ||||||
Peunteun Arus Sirkuit (AC) | (LN) | ISCCR | 20 kA / 50 kA | ||||
TOV Tahan 5s | (LN) | UT | 180V | 335V | 335V | 335V | 580V |
TOV 120 mnt | (LN) | UT | 230V | 440V | 440V | 440V | 765V |
modus | Tahan | Aman Gagal | Aman Gagal | Aman Gagal | Aman Gagal | ||
TOV Tahan 200ms | (N-PE) | UT | 1200V | ||||
Kisaran Suhu Operasi | -40ºF dugi ka +158ºF [-40ºC dugi ka +70ºC] | ||||||
Kalembaban Operasi Diidinan | Ta | 5%…95% | |||||
Tekanan atmosfir sareng luhurna | RH | 80k Pa..106k Pa / -500m..2000m | |||||
Torsi screw Terminal | Mmax | 39,9 lbf-in [4,5 Nm] | |||||
Bagian Palang Konduktor (maks) | 2 AWG (Padet, Terdampar) / 4 AWG (Fléksibel) | ||||||
35 mm2 (Padet, Stranded) / 25 mm2 (Fléksibel) | |||||||
Pamasangan | 35 mm DIN Rel, EN 60715 | ||||||
Gelar panyalindungan | IP 20 (built-in) | ||||||
Bahan Perumahan | Thermoplastic: Extinguishing Gelar UL 94 V-0 | ||||||
Perlindungan termal | Sumuhun | ||||||
Kaayaan Operasi / Indikasi Sesar | Héjo ok / Cacat beureum | ||||||
Kontak Jauh (RC) / Kapasitas Ngalihkeun RC | Pilihan | ||||||
Bagian Palang Konduktor RC (maks) | AC: 250V/0.5A;DC:250V/0.1A;125V/0.2A;75V/0.5A | ||||||
16 AWG (Padet) / 1,5 mm2 (Padet) |