Séri recloser otomatis CJ53RAi mangrupikeun unit kontrol kompak kalayan lébar ngan ukur 18MM, tiasa diadaptasi kana pemutus sirkuit miniatur anu aya di pasaran.
| Modél | Pemutus Sirkuit | ||||||||
| MCB | RCD | RCBO | |||||||
| 1P/2P | 3P/4P | 2P | 4P | 1P | 2P | 3P | 3P+N | 4P | |
| CJ53RAi-1-AC | √ | √ | √ | √ | |||||
| CJ53RAi-2-AC | √ | √ | √ | √ | √ | ||||
| CJ53RAix-1-AC | √ | √ | √ | √ | |||||
| CJ53RAix-2-AC | √ | √ | √ | √ | √ | ||||
| CJ53RAi-1-DC | √ | √ | √ | √ | |||||
| CJ53RAi-2-DC | √ | √ | √ | √ | √ | ||||
| CJ53RAix-1-DC | √ | √ | √ | √ | |||||
| CJ53RAix-2-DC | √ | √ | √ | √ | √ | ||||
| Karakteristik Listrik | |||
| Standar | EN 50557 | ||
| Sistem Distribusi Daya | TT – TN – S | ||
| Tegangan Dipeunteun (Ue) | (V) | 230 AC (1) | |
| Tegangan Dipeunteun Min (Min Ue) | (V) | 85% Ue | |
| Tegangan Nilai Maks (Ue Maks) | (V) | 110% Ue | |
| Tegangan Insulasi Dipeunteun (Ui) | (V) | 500 | |
| Kakuatan Diaelektrik | (V) | 2500 AC salami 1 menit | |
| Tegangan Tahan Dipeunteun (Uimp) | 4 | ||
| Kategori Tegangan Leuwih | III | ||
| Frékuénsi anu Dipeunteun | (Hz) | 50 | |
| Kapasitas Pegat Bocoran Tanah (I△m) | (A) | I△c tina Breaker anu Patali | |
| Arus Sirkuit Pendek Sisa anu Dipeunteun (I△c) | (A) | I△m tina Breaker anu Patali | |
| Urang Polandia | 2 | 4 | |
| Tipe MCB | 1P – 2P – 3P – 4P | ||
| Tipe RCCB | AC – A – A[IR] – A[S] | ||
| Tipe RCBO | |||
| Arus Dipeunteun (Asup) | (A) | 25 – 40 – 63 – 80 – 100 | |
| Arus Sésa Dipeunteun (I△n) | (mA) | 30 – 100 – 300 – 500 | |
| Résistansi non-operasi anu dipeunteun antara komponén listrik sareng taneuh | (kΩ) | 8 (30mA) – 2,5 (100/300/500mA) | |
| Résistansi kerja anu dipeunteun antara bagian anu aktip jeung bumi | (kΩ) | 16 (30mA) – 5 (100/300/500mA) | |
| Dina leungitna kakuatan | (W) | Leungitna daya tina pemutus sirkuit anu aya hubunganana | |
| Kakuatan Statis | (VA) | 1 | 1 |
| Kakuatan nutup deui otomatis | (VA) | 20 | 20 |
| Karakteristik Mékanis | |||
| Lebar Modul DIN | 1 | 1 | |
| Interval Waktu Panutupan Deui | (s) | 10 – 60 – 300 | |
| Frékuénsi Operasi Maks. | (operasi/jam) | 30 | |
| Daya tahan mékanis maksimum (jumlah total operasi) | 10000 | ||
| Siklus Tutup Deui Otomatis Maks. | 60 | ||
| Nomer waktos reset counter Recopper kontinyu operasi | (s) | 3 | |
| Bagian Terminal tina Breaker | (mm²) | Kabel Leuleus: ≤ 1×35 – ≤ 2×16 – ≤ 1×16+2×10 | |
| Torsi pangencangan anu dipeunteun ku pemutus sirkuit | (Nm) | 3 (IDP) – 2 (IDP NA) | |
| Lokasi pamasangan | Naon waé | ||
| Tingkat Protéksi Pemutus Sirkuit | IP20 () – IP40 () | ||
| Karakteristik Lingkungan | |||
| Tingkat Polusi | 2 | ||
| Suhu Padamelan | (°C) | -25 +60 | -25 +60 |
| Suhu Panyimpenan | (°C) | -40 +70 | |
| Kalembaban Relatif | 55°C – Katuhu 95% | ||
| Ciri-ciri Kontak Bantu | |||
| Bantu | Muhun | Muhun | |
| Jenis Kontak | - | Relay Éléktronik | |
| Tegangan anu dipeunteun | (V) | - | 5-230 AC/DC |
| Arus anu dipeunteun | (A) | - | 0.6 (mnt) -1 (maks) |
| Frékuénsi | (Hz) | - | 50 |
| Anggo kategori | - | AC12 | |
| Modeu Operasi | - | Sinyal NO\NC\ Posisi Gagang | |
| Sambungan Kabel | (mm²) | - | ≤2.5 |
| Torsi Pangencangan anu Dipeunteun | (Nm) | - | 0.4 |
| Fungsi Tutup Deui Otomatis | |||
| Tutup Deui Otomatis Nalika Gangguan Listrik Nyetrum | √ | √ | |
| Uji Sesar Bumi | |||
| Uji Bocor Tanah | |||
| Nutup deui Eureun nalika Aya Kasalahan | √ | √ | |
| Sinyal Panutupan Deui | |||
| Indikator Sinyal Kasalahan | √ | √ | |
| Fungsi Otomatis / Manual | √ | √ | |
| Kontak Bantu pikeun Operasi Jarak Jauh | |||
| Protéksi Listrik Internal | PTC | PTC | |